Easy installation with hole in center. Designed for use in civil engineering measurement, these loads on tunnel supports and soil pressure on protective Walls to aid control in construction projects. | Specifications | Accuracy | Rate | capacity (R.C) | 500kgf, 1tf, 2tf, 3tf, 5tf, 10tf, 20tf, 50tf, 100tf, 200tf, 300tf | output (R.O) | 1mv/v±0.4% | Nonlinearity | 1% of R.O. | Hysteresis | 1% of R.O. | Repeatability | 0.2% of R.O. | Zero balance | ±2% of R.O. | Temperature effect | on rated output | 0.05% of LOAD/10℃ | on zero balance | 0.1% of R.O./10℃ | Temperature range | compensated | -10~70℃ | safe | -20~70℃ | Terminal resistance | input | 350 ±50Ω | output | 350 ±2Ω | Insulation resistance bridge | 2000MΩ | Excitation recommended | 10V | Safe overload | 150% R.C | Cable length | Φ7mm 4core, 3m | |
| | Capacity | ΦA | ΦB | ΦC | D | ΦE | F | G | 500kgf | 10 | 35 | 40 | 50 | 18 | 8-M4 DP8 | 1 | --1tf | 18 | 55 | 62 | 70 | 44 | 8-M5 DP8 | 2 | --2tf | 18 | 55 | 62 | 70 | 44 | 8-M5 DP8 | 2 | --3tf | 18 | 55 | 62 | 70 | 44 | 8-M5 DP8 | 2 | --5tf | 18 | 55 | 62 | 70 | 44 | 8-M5 DP8 | 2 | -10tf | 18 | 55 | 62 | 80 | 44 | 8-M5 DP8 | 2 | -20tf | 43 | 68 | 96 | 80 | 56 | 8-M6 DP8 | 3 | -50tf | 80 | 112 | 130 | 110 | 96 | 12-M8 DP10 | 3 | 100tf | 85 | 118 | 158 | 110 | 102 | 12-M12 DP10 | 3 | 200tf | 120 | 190 | 240 | 120 | 156 | 12-M12 DP12 | 3 | 300tf | 120 | 195 | 240 | 120 | 160 | 12-M12 DP12 | 3 | 500tf | 150 | 225 | 265 | 200 | 190 | 12-M16 DP12 | 8 | | | |