6SL3210-1KE12-3UB2
西门子产品订货号:6SL32101KE123UB2
西门子产品价格:168 RMB
西门子产品净重:1.100 Kg
西门子产品承诺:质保一年,原装*
西门子产品尺寸:270.00 x 225.00 x 85.00
概述
SINAMICS G120C, frame sizes FSAA to FSF, with Inligent Operator Panel IOP
SINAMICS G120C compact inverters offer a well-balanced combination of features to address a wide range of applications. They are compact, rugged devices that are easy to operate and can be optionally equipped with a basic or advanced operator panel.
SINAMICS G120C inverters are especially suitable when it comes to meeting the requirements of system integrators, OEMs and distributors regarding high productivity and tailored performance.
优势
- Compact design
- Side-by-side design
- High power density, low envelope dimensions
- Simple installation in the tightest space
- Low space requirement
- Use in small control cabinets, close to the machine
- Optimized parameter set
- Optimized commissioning
- Getting Started document
- BOP‑2 or IOP operator panels can be used
- Integrated USB connection
- Simple and fast software parameter assignment
- Simple to use during commissioning and in operation
- Minimized training costs, existing SINAMICS know-how can be used
- High degree of service friendliness, simple maintenance
- Plug-in terminals
- Cloning function using BOP‑2, IOP or memory card
- Operating hours counter for "drive on" and "motor on"
- Fast mechanical installation
- Intuitive standard commissioning
- Component of Totally Integrated Automation
- Energy-efficient, sensorless vector control
- Automatic flux reduction with V/f ECO
- Integrated energy saving computer
- Safety Integrated (STO)
- Communications versions with PROFINET / EtherNet/IP, PROFIBUS DP, USS/Modbus RTU
- Coated modules
- Operation up to an ambient temperature of 60 °C (140 °F)
设计
SINAMICS G120C is a compact converter for control cabinet mounting in IP20 degree of protection where the Control Unit (CU) and Power Module (PM) function units are combined in one device.
The compact mechanical design and the high power density allow these devices to be installed in machine control enclosures and control cabinets for maximum space utilization. The SINAMICS G120C compact converter can be butt-mounted directly, without derating at temperatures up to 40 °C (104 °F).
SINAMICS G120C, frame size FSAA with BOP-2
SINAMICS G120C can be integrated into the widest range of applications, either using the integrated digital and analog inputs or via the integrated fieldbus interface (available in USS, Modbus RTU, PROFIBUS, PROFINET / EtherNet/IP versions). Especially the product versions with integrated PROFIBUS/PROFINET interface make full integration into the Siemens TIA family possible, therefore allowing the advantages of the seamless TIA product family to be fully utilized. SINAMICS G120C devices are preset in the factory so that they can be immediay connected to PROFIBUS and/or PROFINET fieldbus systems without parameterization.
SINAMICS G120C is also equipped with the safety function STO (Safe Torque Off) as standard, which is used to safely stop drives. As a consequence, machine manufacturers can simply comply with current machinery directives with minimum associated costs.
SINAMICS G120C can control asynchronous (induction) motors in the power range from 0.37 kW up to 132 kW (0.5 hp to 200 hp). Reliable and efficient motor operation is achieved by using state-of-the-art IGBT technology combined with vector control. The extensive range of functions integrated in the SINAMICS G120C also offers a high degree of protection for the converter and motor.
Line-side components
Line reactors
Line reactors smooth the current drawn by the converter and thus reduce harmonic components in the line current. Through the reduction of the current harmonics, the thermal load on the power components in the rectifier and in the DC-link capacitors is reduced as well as the harmonic effects on the supply. The use of a line reactor increases the service life of the converter.
Recommended line-side power components
Standard fuses can be used for the SINAMICS G120C. These must be dimensioned to comply with local regulations. In this chapter, you will find recommended components such as fuses and circuit breakers in compliance with IEC and UL regulations.
DC link components
Braking resistors
Excess energy in the DC link is dissipated in the braking resistor. The braking resistors are designed for use with the SINAMICS G120C. This has an integrated braking chopper (electronic switch).
Load-side power components
Output reactors
Output reactors reduce the rate of voltage rise (dv/dt) and the height of the current peaks, and enable longer motor cables to be connected.
Supplementary system components
Inligent Operator Panel IOP
Graphics-based, user-friendly and powerful operator panel for commissioning and diagnostics as well as local operator control and monitoring of SINAMICS G120C.
Basic Operator Panel BOP-2
A 2-line display to provide support when commissioning and troubleshooting the drive. The drive can be locally controlled.
Memory card
The parameter settings for an inverter can be stored on the SINAMICS SD memory card. When service is required, e.g. after the inverter has been replaced and the data have been downloaded from the memory card the drive system is immediay ready for use again. The associated memory card holder is integrated in the inverter.
PC inverter connection kit 2
For controlling and commissioning an inverter directly from a PC if the STARTER commissioning tool or SINAMICS Startdrive has been installed on the PC.
Spare parts
Shield plates
A set of shield plates is included in the scope of delivery for the motor and signal cables corresponding to the frame size of the SINAMICS G120C, and can also be ordered as spare parts.
Spare parts kit
This kit comprises four I/O terminals, one RS485 terminal, two pairs of Control Unit doors (1 × PN and 1 × other communication versions) and one blanking cover.
Set of connectors
A set of connectors for the line feeder cable, braking resistor and motor cable can be ordered corresponding to the frame size of the SINAMICS G120C inverter.
Roof-mounted fan
A roof-mounted fan (at the top of the device) comprising a pre-assembled unit with holder and fan can be ordered corresponding to the frame size of the SINAMICS G120C.
Fan unit
A replacement fan (at the rear of the device; heat sink) comprising a pre-assembled unit with holder and fan can be ordered corresponding to the frame size of the SINAMICS G120C.
集成
Connection example for SINAMICS G120C
USS/Modbus RTU communication interface
PROFIBUS DP communication interface
PROFINET, EtherNet/IP communication interface
6SL3210-1KE12-3UB2
西门子产品订货号:6SL32101KE123UB2
西门子产品价格:168 RMB
西门子产品净重:1.100 Kg
西门子产品承诺:质保一年,原装*
西门子产品尺寸:270.00 x 225.00 x 85.00
Control Units | Power Modules degree of protection IP20 | |
---|---|---|
| PM240‑2/PM240 | PM250 |
CU230P‑2 | ✓ | ✓ |
CU240E‑2 | ✓ | ✓ |
CU250S‑2 | ✓ | ✓ |
PM240, PM240‑2 and PM250 Power Modules
Rated power 1) |
| Rated output current Irated2) | PM240‑2 Power Modules 3) All CUs pluggable | PM250 All CUs pluggable |
---|---|---|---|---|
kW | hp | A | Article No. | Article No. |
200 ... 240 V 1 AC/3 AC | ||||
0.55 | 0.75 | 3.2 | 6SL3210-1PB13-0❒L0 | – |
0.75 | 1 | 4.2 | 6SL321❒-1PB13-8❒L0 | – |
1.1 | 1.5 | 6 | 6SL3210-1PB15-5❒L0 | – |
1.5 | 2 | 7.4 | 6SL3210-1PB17-4❒L0 | – |
2.2 | 3 | 10.4 | 6SL321❒-1PB21-0❒L0 | – |
3 | 4 | 13.6 | 6SL3210-1PB21-4❒L0 | – |
4 | 5 | 17.5 | 6SL321❒-1PB21-8❒L0 | – |
200 ... 240 V 3 AC | ||||
5.5 | 7.5 | 22 | 6SL3210-1PC22-2❒L0 | – |
7.5 | 10 | 28 | 6SL3210-1PC22-8❒L0 | – |
11 | 15 | 42 | 6SL3210-1PC24-2UL0 | – |
15 | 20 | 54 | 6SL3210-1PC25-4UL0 | – |
18.5 | 25 | 68 | 6SL3210-1PC26-8UL0 | – |
22 | 30 | 80 | 6SL3210-1*-0UL0 | – |
30 | 40 | 104 | 6SL3210-1PC31-1UL0 | – |
37 | 50 | 130 | 6SL3210-1PC31-3UL0 | – |
45 | 60 | 154 | 6SL3210-1PC31-6UL0 | – |
55 | 75 | 178 | 6SL3210-1PC31-8UL0 | – |
380 ... 480 V 3 AC | ||||
0.37 4) | 0.5 | 1.3 | – 4) | – |
0.55 | 0.75 | 1.7 | 6SL3210-1PE11-8❒L1 | – |
0.75 | 1 | 2.2 | 6SL3210-1PE12-3❒L1 | – |
1.1 | 1.5 | 3.1 | 6SL3210-1PE13-2❒L1 | – |
1.5 | 2 | 4.1 | 6SL3210-1PE14-3❒L1 | – |
2.2 | 3 | 5.9 | 6SL3210-1PE16-1❒L1 | – |
3 | 4 | 7.7 | 6SL321❒-1PE18-0❒L1 | – |
4 | 5 | 10.2 | 6SL3210-1PE21-1❒L0 | – |
5.5 | 7.5 | 13.2 | 6SL3210-1PE21-4❒L0 | – |
7.5 | 10 | 18 | 6SL321❒-1PE21-8❒L0 | 6SL3225-0BE25-5AA1 |
11 | 15 | 26/25 | 6SL3210-1PE22-7❒L0 | 6SL3225-0BE27-5AA1 |
15 | 20 | 32 | 6SL321❒-1PE23-3❒L0 | 6SL3225-0BE31-1AA1 |
18.5 | 25 | 38 | 6SL3210-1PE23-8❒L0 | 6SL3225-0BE31-5❒A0 |
22 | 30 | 45 | 6SL3210-1PE24-5❒L0 | 6SL3225-0BE31-8❒A0 |
30 | 40 | 60 | 6SL3210-1PE26-0❒L0 | 6SL3225-0BE32-2❒A0 |
37 | 50 | 75 | 6SL3210-1PE27-5❒L0 | 6SL3225-0BE33-0❒A0 |
45 | 60 | 90 | 6SL3210-1PE28-8❒L0 | 6SL3225-0BE33-7❒A0 |
55 | 75 | 110 | 6SL3210-1PE31-1❒L0 | 6SL3225-0BE34-5❒A0 |
75 | 100 | 145 | 6SL3210-1PE31-5❒L0 | 6SL3225-0BE35-5❒A0 |
90 | 125 | 178 | 6SL3210-1PE31-8❒L0 | 6SL3225-0BE37-5❒A0 |
110 | 150 | 205 | 6SL3210-1PE32-1❒L0 | – |
132 | 200 | 250 | 6SL3210-1PE32-5❒L0 | – |
160 3) | 250 | 302 | 6SL3224-0XE41-3UA0 | – |
200 3) | 300 | 370 | 6SL3224-0XE41-6UA0 | – |
250 3) | 400 | 477 | 6SL3224-0XE42-0UA0 | – |
500 ... 690 V 3 AC | ||||
11 | 10 | 14 | 6SL3210-1PH21-4❒L0 | – |
15 | 15 | 19 | 6SL3210-1PH22-0❒L0 | – |
18.5 | 20 | 23 | 6SL3210-1PH22-3❒L0 | – |
22 | 25 | 27 | 6SL3210-1PH22-7❒L0 | – |
30 | 30 | 35 | 6SL3210-1PH23-5❒L0 | – |
37 | 40 | 42 | 6SL3210-1PH24-2❒L0 | – |
45 | 50 | 52 | 6SL3210-1PH25-2❒L0 | – |
55 | 60 | 62 | 6SL3210-1PH26-2❒L0 | – |
75 | 75 | 80 | 6SL3210-1PH28-0❒L0 | – |
90 | 100 | 100 | 6SL3210-1PH31-0❒L0 | – |
110 | 100 | 115 | 6SL3210-1PH31-2❒L0 | – |
132 | 125 | 142 | 6SL3210-1PH31-4❒L0 | – |
Heat sink variant |
|
| ↑ |
|
Standard |
|
| 0 |
|
Push Through |
|
| 1 |
|
Integrated line filter |
|
| ↑ | ↑ |
Without | (for IT systems) |
| U | U |
Class A | (for TN systems) |
| A | A |
Class B | (for TN systems) |
| – | Integrated line filter not available, as external option only |
西门子产品订货号:6SL32101KE123UB2
西门子产品价格:168 RMB
西门子产品净重:1.100 Kg
西门子产品承诺:质保一年,原装*
西门子产品尺寸:270.00 x 225.00 x 85.00
S7-300 CPU的微存储卡
基于FEPROM的微存储卡简称为MMC,用于在断电时保存用户程序和某些数据。
MMC用来作S7、C7和ET 200S的CPU的装载存储器,程序和数据下载后保存在MMC内。如果CPU未插MMC,不能下载STEP 7的程序和数据。应当注意,不能带电插拔MMC,否则会丢失程序或损坏MMC。西门子的PLC必须使用西门子的MMC,不能使用数码产品使用的通用型MMC。
不能用CPU的模式选择开关的操作来删除下载到MMC的系统数据和程序。为了完成上述操作,首先建立好PLC与计算机之间的通信连接,点击SIMATIC管理器工具栏上的在线按钮,打开在线视图,选中块文件夹中需要删除的块,按计算机键盘上的<Delete>(删除)键,删除它们。不能删除CPU中集成的SFB和SFC块。
如果忘记了密码,只能用西门子的编程器上的读卡槽或用西门子带USB接口的读卡器,使用SIMATIC管理器的菜单命令“文件”→“S7存储卡”→“删除”命令,删除MMC上的程序、数据和密码,这样MMC就可以作为一个未加密的空卡使用了。