SUCO压力开关选型大全
2017-7-25 阅读(860)
0110 / 0112 / 0114 / 0116 / 0118 / 0122
Diaphragm pressure switches with integrated connector
- Setting ranges to up to 725 psi (50 bar) (higher settings refer to page 26)
- NC or NO, maximum voltage 42 V
- Zinc-plated steel (Cr VI-free)
- Overpressure safety up to 4,350 psi (300 bar)1)
Plug-in types for diaphragm pressure switches |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| |
Deutsch DT04-2P |
|
| 0110 – XXX XX – X – XXX |
| 0110 – XXX XX – X – XXX |
| |||
|
|
|
|
|
|
|
|
| |
AMP Superseal 1.5® |
|
| 0112 – XXX XX – X – XXX |
| 0112 | – XXX XX – X – XXX |
| ||
|
|
|
|
|
|
|
|
| |
Packard MetriPack 280® |
|
| 0114 – XXX XX – X – XXX |
| 0114 – XXX XX – X – XXX |
| |||
|
|
|
|
|
|
|
|
| |
Deutsch DT04-3P (A+B) |
|
| 0116 – XXX XX – X – XXX |
| 0116 – XXX XX – X – XXX |
| |||
|
|
|
|
|
|
|
|
| |
AMP Junior Timer® |
|
| 0118 – XXX XX – X – XXX |
| 0118 – XXX XX – X – XXX |
| |||
|
|
|
|
|
|
|
|
| |
M12x1 DIN EN 61076-2-101-A | 0122 – XXX XX – X – XXX |
| 0122 | – XXX XX – X – XXX |
| ||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
Adjustment range | Male |
| Order number |
| Order number |
| |||
tolerance at room temperature | thread |
| NO —› |: |
| NC —› :| |
|
|
| |
|
|
|
|
|
|
|
|
|
|
Diaphragm pressure switches with integrated connector |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| |
| M 10x1 taper |
| XXXX – 403 01 – X – 009 |
| XXXX – 404 01 – X – 013 |
| |||
| 1/4” BSPP |
| XXXX – 403 03 – X – 011 |
| XXXX – 404 03 – X – 015 |
| |||
1.45 - 14.5 ± 2.90 psi |
|
|
|
|
|
|
|
|
|
1/8” NPT |
| XXXX – 403 04 – X – 012 |
| XXXX – 404 04 – X – 016 |
| ||||
(0.1 - 1 ± 0.2 bar) |
|
|
| ||||||
1/4” NPT |
| XXXX – 403 09 – X – 345 |
| XXXX – 404 | 09 – X – 346 |
| |||
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| |
| 7/16 - 20 UNF |
| XXXX – 403 20 – X – 305 |
| XXXX – 404 20 – X – 307 |
| |||
|
|
|
|
|
|
|
|
| |
| 9/16 - 18 UNF |
| XXXX – 403 21 – X – 306 |
| XXXX – 404 21 – X – 308 |
| |||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
| M 10x1 taper |
| XXXX – 423 01 – X – 070 |
| XXXX – 424 01 – X – 070 |
| |||
| 1/4” BSPP |
| XXXX – 423 03 – X – 070 |
| XXXX – 424 03 – X – 070 |
| |||
|
|
|
|
|
|
|
|
| |
7.25 - 43.5 ± 4.35 psi | 1/8” NPT |
| XXXX – 423 04 – X – 070 |
| XXXX – 424 04 – X – 070 |
| |||
(0.5 - 3 ± 0.3 bar) | 1/4” NPT |
| XXXX – 423 09 – X – 070 |
| XXXX – 424 | 09 – X – 070 |
| ||
| 7/16 - 20 UNF |
| XXXX – 423 20 – X – 070 |
| XXXX – 424 | 20 – X – 070 |
| ||
|
|
|
|
|
|
|
|
| |
| 9/16 - 18 UNF |
| XXXX – 423 21 – X – 070 |
| XXXX – 424 21 – X – 070 |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| M 10x1 taper |
| XXXX – 407 01 – X – 025 |
| XXXX – 408 | 01 – X – 029 |
| ||
| 1/4” BSPP |
| XXXX – 407 03 – X – 027 |
| XXXX – 408 03 – X – 031 |
| |||
|
|
|
|
|
|
|
|
| |
14.5 - 145 ±7.25 psi | 1/8” NPT |
| XXXX – 407 04 – X – 028 |
| XXXX – 408 04 – X – 032 |
| |||
(1 - 10 ± 0.5 bar) | 1/4” NPT |
| XXXX – 407 09 – X – 349 |
| XXXX – 408 | 09 – X – 350 |
| ||
| 7/16 - 20 UNF |
| XXXX – 407 20 – X – 313 |
| XXXX – 408 | 20 – X – 315 |
| ||
|
|
|
|
|
|
|
| ||
| 9/16 - 18 UNF |
| XXXX – 407 21 – X – 314 |
| XXXX – 408 21 – X – 316 |
| |||
|
|
|
|
|
|
|
|
|
|
Seal material – Application areas |
|
|
|
|
|
|
| ||
|
|
|
|
|
| ||||
NBR (BunaN) | Hydraulic/machine oil, heating oil, air, nitrogen, etc. |
| 1 |
| |||||
|
|
|
|
|
|
|
| ||
EPDM | Brake fluid, hydrogen, oxygen, acetylene, etc. |
|
|
| 2 |
| |||
|
|
|
|
|
| ||||
FKM (Viton®) | Hydraulic fluids (HFA, HFB, HFD), petrol/gasoline, etc. |
| 3 |
| |||||
|
|
|
|
|
|
|
| ||
HNBR | Hydraulic/machine oil, ester-based bio-oils |
|
|
| 9 |
| |||
|
|
|
|
| |||||
Refer to page 24 for the temperature range and application thresholds of sealing materials. |
|
|
| ||||||
|
|
| |||||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| Your order number: |
| 01XX – XXX XX – X – XXX |
| |||||
|
|
|
|
|
|
|
|
|
|