Open IE communication | | | | | | |
| | | | | | |
| 8 kbyte | 8 kbyte | 8 kbyte | 8 kbyte | 8 kbyte | 8 kbyte |
| Yes | Yes | Yes | Yes | Yes | Yes |
| 8 kbyte | 8 kbyte | 8 kbyte | 8 kbyte | 8 kbyte | 8 kbyte |
| | | | | | |
| 1 472 byte | 1 472 byte | 1 472 byte | 1 472 byte | 1 472 byte | 1 472 byte |
Further protocols | | | | | | |
| Yes | Yes | Yes | Yes | Yes | Yes |
Communication functions | | | | | | |
S7 communication | | | | | | |
| Yes | Yes | Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes | Yes | Yes |
| See online help (S7 communication, user data size) | See online help (S7 communication, user data size) | See online help (S7 communication, user data size) | See online help (S7 communication, user data size) | See online help (S7 communication, user data size) | See online help (S7 communication, user data size) |
Open IE communication | | | | | | |
| Yes | Yes | Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes | Yes | Yes |
Web server | | | | | | |
| Yes | Yes | Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes | Yes | Yes |
Number of connections | | | | | | |
| | | 16; dynamically | 16; dynamically | 16; dynamically | 16; dynamically |
Test commissioning functions | | | | | | |
Status/control | | | | | | |
| Yes | Yes | Yes | Yes | Yes | Yes |
| Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
Forcing | | | | | | |
| Yes | Yes | Yes | Yes | Yes | Yes |
Diagnostic buffer | | | | | | |
| Yes | Yes | Yes | Yes | Yes | Yes |
Traces | | | | | | |
| 2 | 2 | 2 | 2 | 2 | 2 |
| 512 kbyte | 512 kbyte | 512 kbyte | 512 kbyte | 512 kbyte | 512 kbyte |
Interrupts/diagnostics/status information | | | | | | |
Diagnostics indication LED | | | | | | |
| | | | | Yes | Yes |
| | | | | Yes | Yes |
| | | | | Yes | Yes |
Integrated Functions | | | | | | |
Number of counters | 4 | 4 | 6 | 6 | 6 | 6 |
Counting frequency (counter) max. | 100 kHz | 100 kHz | 100 kHz | 100 kHz | 100 kHz | 100 kHz |
Frequency meter | Yes | Yes | Yes | Yes | Yes | Yes |
controlled positioning | Yes | Yes | Yes | Yes | Yes | Yes |
Number of position-controlled positioning axes, max. | 8 | 8 | 8 | 8 | 8 | 8 |
Number of positioning axes via pulse-direction interface | Up to 4 with SB 1222 | Up to 4 with SB 1222 | Up to 4 with SB 1222 | Up to 4 with SB 1222 | 4; With integrated outputs | Up to 4 with SB 1222 |
PID controller | Yes | Yes | Yes | Yes | Yes | Yes |
Number of alarm inputs | 4 | | 4 | 4 | 4 | 4 |
Number of pulse outputs | 4 | 4 | | | 4 | |
Limit frequency (pulse) | 100 kHz | | | | 100 kHz | |
Potential separation | | | | | | |
Potential separation digital inputs | | | | | | |
| 500V AC for 1 minute | 500V AC for 1 minute | Functional isolation (Optocoupler) | | No | 500V AC for 1 minute |
| 1 | 1 | | | 1 | 1 |
Potential separation digital outputs | | | | | | |
| Yes | Relays | | | Yes | Relays |
| No | No | | | No | No |
| 1 | 1 | | | 1 | 2 |
Permissible potential difference | | | | | | |
between different circuits | 500 V DC between 24 V DC and 5 V DC | 500 V DC between 24 V DC and 5 V DC | | | | |
EMC | | | | | | |
Interference immunity against discharge of static electricity | | | | | | |
| Yes | Yes | Yes | Yes | Yes | Yes |
| 8 kV | 8 kV | 8 kV | 8 kV | 8 kV | 8 kV |
| 6 kV | 6 kV | 6 kV | 6 kV | 6 kV | 6 kV |
Interference immunity to cable-borne interference | | | | | | |
| Yes | Yes | Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes | Yes | Yes |
Interference immunity against voltage surge | | | | | | |
| Yes | Yes | Yes | Yes | Yes | Yes |
Interference immunity against conducted variable disturbance induced by high-frequency fields | | | | | | |
| Yes | Yes | Yes | Yes | Yes | Yes |
Emission of radio interference acc. to EN 55 011 | | | | | | |
| Yes; Group 1 | Yes; Group 1 | Yes; Group 1 | Yes; Group 1 | Yes; Group 1 | Yes; Group 1 |
| Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 | Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 | Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 | Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 | Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 | Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 |
Degree and class of protection | | | | | | |
Degree of protection acc. to EN 60529 | | | | | | |
| Yes | Yes | Yes | | Yes | Yes |
Standards, approvals, certificates | | | | | | |
CE mark | Yes | Yes | Yes | Yes | Yes | Yes |
UL approval | Yes | Yes | Yes | Yes | Yes | Yes |
cULus | Yes | Yes | Yes | Yes | Yes | Yes |
FM approval | Yes | Yes | Yes | Yes | Yes | Yes |
RCM (formerly C-TICK) | Yes | Yes | Yes | Yes | Yes | Yes |
KC approval | Yes | Yes | Yes | Yes | Yes | Yes |
Marine approval | Yes | Yes | Yes | Yes | Yes | Yes |
Highest safety class achievable in safety mode | | | | | | |
| PLe | PLe | PLe | PLe | PLe | PLe |
| SIL 3 | SIL 3 | SIL 3 | SIL 3 | SIL 3 | SIL 3 |
Ambient conditions | | | | | | |
Free fall | | | | | | |
| 0.3 m; five times, in product package | 0.3 m; five times, in product package | 0.3 m; five times, in product package | | 0.3 m; five times, in product package | 0.3 m; five times, in product package |
Ambient temperature during operation | | | | | | |
| 0 °C | 0 °C | 0 °C | 0 °C | 0 °C | 0 °C |
| 55 °C | 55 °C | 55 °C | 55 °C | 55 °C | 55 °C |
| 0 °C | 0 °C | 0 °C | 0 °C | 0 °C | 0 °C |
| 55 °C | 55 °C | 55 °C | 55 °C | 55 °C | 55 °C |
| 0 °C | 0 °C | 0 °C | 0 °C | 0 °C | 0 °C |
| 45 °C | 45 °C | 45 °C | 45 °C | 45 °C | 45 °C |
Ambient temperature during storage/transportation | | | | | | |
| -40 °C | -40 °C | -40 °C | -40 °C | -40 °C | -40 °C |
| 70 °C | 70 °C | 70 °C | 70 °C | 70 °C | 70 °C |
Air pressure acc. to IEC 60068-2-13 | | | | | | |
| | | | | 795 hPa | 795 hPa |
| | | | | 1 080 hPa | 1 080 hPa |
| 660 hPa | 660 hPa | 660 hPa | 660 hPa | 660 hPa | 660 hPa |
| 1 139 hPa | 1 139 hPa | 1 139 hPa | 1 139 hPa | 1 080 hPa | 1 080 hPa |
| -1000 to 2000 m | -1000 to 2000 m | -1000 to 2000 m | -1000 to 2000 m | -1000 to 2000 m | -1000 to 2000 m |
Relative humidity | | | | | | |
| 95 %; no condensation | 95 %; no condensation | 95 %; no condensation | 95 %; no condensation | 95 %; no condensation | 95 %; no condensation |
Vibrations | | | | | | |
| 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail | 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail | 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail | 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail | 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail | 2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail |
| Yes | Yes | Yes | Yes | Yes | Yes |
Shock test | | | | | | |
| Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms |
Pollutant concentrations | | | | | | |
| S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free |
Programming | | | | | | |
Programming language | | | | | | |
| Yes; incl. failsafe | Yes; incl. failsafe | Yes; incl. failsafe | Yes; incl. failsafe | Yes; incl. failsafe | Yes; incl. failsafe |
| Yes; incl. failsafe | Yes; incl. failsafe | Yes; incl. failsafe | Yes; incl. failsafe | Yes; incl. failsafe | Yes; incl. failsafe |
| Yes | Yes | Yes | Yes | Yes | Yes |
Know-how protection | | | | | | |
| Yes | Yes | Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes | Yes | Yes |
| Yes | Yes | Yes | Yes | Yes | Yes |
Access protection | | | | | | |
| | | | | Yes | Yes |
| | | | | Yes | Yes |
| | | | | Yes | Yes |
Cycle time monitoring | | | | | | |
| Yes | Yes | Yes | Yes | Yes | Yes |
Dimensions | | | | | | |
Width | 90 mm | 90 mm | 110 mm | 110 mm | 130 mm | 130 mm |
Height | 100 mm | 100 mm | 100 mm | 100 mm | 100 mm | 100 mm |
Depth | 75 mm | 75 mm | 75 mm | 75 mm | 75 mm | 75 mm |
Weights | | | | | | |
Weight, approx. | 370 g | 385 g | 435 g | 435 g | 585 g | 585 g |