设备描述AQ6317AndoAQ6317光谱分析仪TheAQ6317isanadvancedopticalspectrumanalyzerforawiderangeofapplications

详细介绍

设备描述

AQ6317 Ando AQ6317光谱分析仪

The AQ6317 is an advanced optical spectrum analyzer for a wide range of applications, including light source evaluation, measurement of loss wavelength characteristicsin optical devices, and waveform analysis of WDM (Wavelength Division Multiplexing) systems.Especially at 1550 nm band, the unit achieves high wavelength accuracy and wavelength linearity, and can evaluate optical devices for WDM. Analysis functions make operation and expandability simple.

The AQ6317 contains the latest of Ando’s technology for optical spectrum analyzers. A reference equipment for the next generation.

Features:_ 50 GHz WDM-SignalsHigh-resolution measurement in a wide 50 GHz spectrum dynamic range._ Versatile analysis functionsAnalysis functions for WDM and other optical devices (LD, LED, FBG, etc.)_ High wavelength accuracy

Provides ±0.05 nm wavelength accuracy in the 1550 nm band, with ±0.01 nm wavelength linearity, making it especially useful for high-precision loss wavelength characteristic and other evaluation of WDM devices.The wavelength scale indicates both in air and in vacuum._ Synchronous sweepIn conjunction with a AQ4320 Tunable Laser Source, much higher wavelength resolution/wide dynamic range can be achieved by high-speed synchronous sweep._ High wavelength resolutionAchieves wavelength resolution of 0.015 nm_ High sensitivity over a wide band

Covers from 600 nm to 1750 nm and high sensitivity allow measurement of light at down to -90 dBm._ Low polarization dependancyMeasurements such as gain of optical amplifier can be proceeded accurately because polarization dependency is suppressed as low as ±0.05 dB._ High-level accuracyAccurate within a ±0.3 dB._ High power measurement: Max. +20 dBm (100 mW)Even high-power output from an optical amplifier can be measured directly without an optical attenuator._ 9.4-inch color LCD_ Pulsed light can be measured_ Three individual trace memories