¥面议
上海南浦仪表厂
产品介绍
航空插件式热电偶
主要技术指标Major technical indexes | |||||||||
铠装热电偶种类、温度范围及允差 Temperature measuring range and accurancy | |||||||||
类别Category | 代号 | 分度号 | 套管外径(mm) | 测量范围 ℃ | *高使用温度(℃) | 允许偏差△tTolerance | |||
1 | 2 | ||||||||
镍铬-铜镍 Nickel-chromium--cupronickel | WREK | E | ≥φ3 | -40~700 | 700 | ±1.5℃或±0.4%t±1.5℃ or±0.4%t | ±2.5℃或±0.75%t±2.5℃ or ±0.75%t | ||
WRNK | K | | -40~900 | 950 | | ||||
WRJK | J | | -40~500 | 600 | | ||||
WRCK | T | | -40~350 | 400 | | ||||
铂铑-铂 Rhodium Platinum-Platinum | WRPK | S | φ5~φ8 | 0~1100 | 1300 | ±1.5℃ or±0.25%t | | ||
常温绝缘电阻Insulation resistance at normal temperature 绝缘型铠装热电偶在环境温度为20±15℃,相对湿度不大于80%时,热电极与外套管之间的绝缘电阻应符合下表的规定: | |||||||||
Of the insulated sheathed thermocouple, the insulation resistance between thermode and outer tube shall, under the ambient termperature of 20±15℃ and relative humidity not more than 80%, comply with the stipulation as below: | |||||||||
铠装热电偶直径d(mm) Diameter of sheathed thermocouple | 试验电压(V·DC) Ecperimental voltage | 绝缘电阻(MΩ·m) Insulation resistance | |||||||
0.5~1.5 | 50±5 | ≥1000 | |||||||
>1.5 | 500±50 | ≥1000 | |||||||
注:绝缘电阻用(MΩ·m)表示。即1m长的试样的绝缘电阻为1000MΩ;10m长的试样的绝缘电阻为100MΩ。Note: The insulation resistance shall be denoted as( MΩ·m) , namly, the insulation resisance of 1m-long specimen is 1000( MΩ·m) and that of the 10m-long is 100MΩ. | |||||||||
铠装热电偶可绕半径Windable radius of sheathed thermocouple 铠装热电偶的可绕半径不应小于其直径的5倍,并没有明显的损伤。 | |||||||||
The windable radius of sheathed thermocouple shall not less than 5 times of its |