PLC 工控机 嵌入式系统 人机界面 工业以太网 现场总线 变频器 机器视觉 DCS PAC/PLMC SCADA 工业软件 ICS信息安全 应用方案 无线通讯
上海文顺电器有限公司
暂无信息 |
ProductDescription:Thekeyfacilitiesofthedatacenterarepowerdistributionandairconditioningsystems,andthecomprehensivetestistheloadtestofkeyfacilities
Product Description: The key facilities of the data center are power distribution and air conditioning systems, and the comprehensive test is the load test of key facilities. The IT equipment is gradually installed after the data center is delivered for use, that is, there is no it load in the data center during construction acceptance, so many problems of key facilities cannot be exposed. Therefore, false load arises at the historic moment. Simulate the actual operation and heating of IT equipment through dummy load to ensure the effective operation of data center power supply and company system (including UPS system), air conditioning fresh air system, lightning protection and grounding system, monitoring system and other systems, and timely find and solve problems through testing, so as to eliminate potential safety hazards. Product importance: Fake load verification test, as a comprehensive inspection and test before the new data center is put into operation, has been recognized and supported by more and more people in the industry. And as an indispensable key project link in the new data center project. The introduction of this link plays a very important role in the project, operation and data center life cycle management. It can eliminate hidden dangers in advance, establish operation and maintenance procedures and carry out operation drills. It is also the final guarantee for the overall project delivery quality. At this stage, the hidden dangers buried in design, construction and equipment can be rectified at the least cost, so as to avoid the systematic risk of the project. Application fields: Acceptance of the refrigeration system in the machine room, provision of acceptance report on the air flow environment in the machine room, verification of the design index of the machine room, and acceptance of the power system in the machine room | ||
Product name | Data center high voltage load | |
model | WS-642000 | |
The main technical indexes and parameters of the load box can be customized according to customer needs | ||
Rated voltage | AC 10.5KV | |
Rated power | 2000KW | |
Maximum current | 110A | |
Minimum step | 100KW | |
accuracy | ≤1%F.S. | |
control mode | Manual | Programmable |
Panel layout | power switch | power switch |
Communication protocol | NA | Modbus RTU communication protocol |
Load mode | < constant resistance > | < constant resistance > |
Data monitoring | Three phase voltage, three-phase current, three-phase power, power factor, frequency and other parameters | |
Voltage resolution | ≤1%F.S. | ≤1%F.S. |
Current resolution | ≤1%F.S. | ≤1%F.S. |
Protection function | Short circuit protection of working power supply | Short circuit protection of working power supply |
Heat dissipation mode | Forced air cooling | |
Working power supply | AC 380V 50Hz | |
Installation mode | Outdoor, 20 foot container | |
Overall dimension | 6058*2438*2591mm | |
Equipment weight | 4T | |
Appearance color | Ral7032 light grey |
您感兴趣的产品PRODUCTS YOU ARE INTERESTED IN
智能制造网 设计制作,未经允许翻录必究 .
请输入账号
请输入密码
请输验证码
请输入你感兴趣的产品
请简单描述您的需求
请选择省份