详细介绍
电气规格
说明 | MD882 | |||
zui小值 | 典型值 | zui大值 | 单位 | |
输出电流 | 1.8 | —— | 7.8(均值5.6) | A |
输入电源电压 | 24 | 68 | 80 | VDC |
控制信号输入电流 | 7 |
| 16 | mA |
步进脉冲频率 | 0 |
| 300 | KHz |
脉冲低电平时间 | 1.5 |
|
| μs |
绝缘电阻 | 500 |
|
| MΩ |
电流设定
峰值(A) | 平均值(A) | SW1 | SW2 | SW3 |
1.80 | 1.30 | Off | Off | Off |
2.50 | 1.80 | On | Off | Off |
3.50 | 2.50 | Off | On | Off |
4.30 | 3.10 | On | On | Off |
5.20 | 3.70 | Off | Off | On |
6.00 | 4.30 | On | Off | On |
7.00 | 5.00 | Off | On | On |
7.80 | 5.60 | On | On | On |
细分设定
步数/圈(1.8°/整步) | SW5 | SW6 | SW7 | SW8 |
200 | OFF | OFF | OFF | OFF |
400 | ON | OFF | OFF | OFF |
500 | OFF | ON | OFF | OFF |
800 | ON | ON | OFF | OFF |
1000 | OFF | OFF | ON | OFF |
1250 | ON | OFF | ON | OFF |
1600 | OFF | ON | ON | OFF |
2000 | ON | ON | ON | OFF |
2500 | OFF | OFF | OFF | ON |
3200 | ON | OFF | OFF | ON |
4000 | OFF | ON | OFF | ON |
5000 | ON | ON | OFF | ON |
6400 | OFF | OFF | ON | ON |
8000 | ON | OFF | ON | ON |
1000 | OFF | ON | ON | ON |
12800 | ON | ON | ON | ON |
P1弱电接线信号描述
名称 | 功能 |
PUL+(+5V) | 脉冲控制信号:脉冲上升沿有效;PUL-高电平时4-5V,低电平时0-0.5V。为了可靠响应脉冲信号,脉冲宽度应大于2.5μs。如采用+12V或+24V时需串电阻。 |
PUL-(PUL) | |
DIR+(+5V) | 方向信号:高/低电平信号,为保证电机可靠换向,方向信号应先于脉冲信号至少 5μs建立。电机的初始运行方向与电机的接线有关,互换任一相绕组(如A+、A-交换)可以改变电机初始运行的方向,DIR-高电平时4-5V,低电平时0-0.5V。 |
DIR-(DIR) | |
ENA+(+5V) | 使能信号:当此信号处于高电平状态,驱动器使电机线圈有电流流过,处于锁紧状态;当此信号处于低电平状态,驱动器使电机无电流,处于松弛状态。只在某些特殊场合有用,一般情况下不用,可以不接,驱动器照常使电机运转。 |
ENA-(ENA) |
P2强电接口描述
名称 | 功能 |
GND | 直流电源地 |
+V | 直流电源正极,+24V—+80V间任何值均可,但*值+68VDC左右。 |
A+、A- | 电机A相线圈。 |
B+、B- | 电机B相线圈。 |
接线图
外形尺寸(单位:毫米)