71系列耐压绝缘测试仪器
产品介绍
四种测试顺序可供选择:w, i, w-i, i-w
可与7305接地阻抗测试器连结使用
内建5组程序内存缓升及测试时间可达999.9秒
键盘锁定功能内建plc remote可程序遥控界面前面板软件输入校正
操作简单体积小、重量轻
specifications
model
7110
7112
7120
7122
ac withstand voltage
output rating
5kvac/12ma
 
range
resolution
accuracy
output voltage, kvac
0-5.00
0.01
±(2% of setting + 5v)
output frequency
50hz/60hz ±100ppm, user se-lection
output waveform
sine wave ,thd.<2% (resistive load), crest factor = 1.3 - 1.5
output regulation
± (1% of output + 5v), from no load to full load
settings
hi-limit ac current, ma
0.10 - 12.00
0.01
±(2% of setting + 2counts)
lo-limit ac current, ma
0.00 - 12.00
0.01
±(2% of setting + 2counts)
ramp time, second
0.1 - 999.9
0.1
±(0.1% + 0.05sec)
dwell time, second
0, 0.2 - 999.9
(0=continuous)
0.1
arc detection
0, 1 - 9 ranges (0=off, 9 is the most sensitivity)
dc withstand voltage (7120,7122 only)
output rating
6kvdc/5ma
output voltage, kvdc
0 - 6.00
0.01
±(2% of setting + 5v)
output ripple
<5%(6kv/5ma at resistive load)
settings
hi-limit dc current, ma
0.02 - 5.00
0.01
±(2% of setting + 2counts)
lo-limit dc current, ma
0.00 - 5.00
0.01
±(2% of setting + 2counts)
ramp time, second
0.1 - 999.9
0.1
±(0.1% + 0.05sec)
dwell time, second
0, 0.2 - 999.9
(0=continuous)
0.1
arc detection
0, 1 - 9 ranges (0=off, 9 is the most sensitivity)
discharge time
< 200 msec
insulation resistance (7112,7122 only)
output rating
1kvdc/1000mω
output voltage, kvdc
0.10 - 1.00
0.01
±(2% of setting + 3v)
settings
hi-limit resistance, mω
0, 1 - 1000 (0=off)
1
±(3% of setting+2counts)at > 500vdc
lo-limit resistance, mω
1 - 1000
1
±(7% of setting +2counts)at <500vdc
delay time, second
0, 0.5 - 999.9
(0=continuous)
0.1
±(0.1% + 0.05sec)
measurement
ac/dc voltage, kv
0 - 6.00
0.01
±(1.5% of reading + 1count)
dc voltage, kv (ir only)
0.10 - 1.00
0.01
±(1.5% of reading + 3v)
ac current, ma
0.10 - 12.00
0.01
±(2% of reading + 2counts)
dc current, ma
0.02 - 5.00
0.01
±(2% of reading + 2counts)
resistance, mω
1 - 1000
(auto range)
0.001
0.01
0.1
±(3% of reading+2counts)at > 500vdc
±(7% of reading +2counts)at <500vdc
general
input voltage ac
115/230vac±15%, 50/60hz ± 5%, fuse 3.15a fast
plc remote control
input : test , reset
output : pass , fail , processing
memory
5 sets store/recall of each memory, 4 test mode se-lectable (w, i, w~i, i~w only 7112, 7122)
display
16×2 lcd with back light
key lock
to prevent unauthorized alteration of the test parameters
calibration
build-in software and external calibrated meters
environment
0-40℃, 20-80%rh
dimension/net weight
280mm(w)×89mm(h)×370mm(d)/ 9kg
standard accessories
power cord(10a)
×1
fuses
×3 (including a spare contained in the fuse holder)
hipot test lead ,1.5m(1101)
×1
hipot return lead ,1.8m(1102)
×1