NRP/NRP2功率计在电子测试与测量领域中,精确测量射频功率是挑战性的任务之一。无论是在测量移动通信中的某个射频模块,或是在复杂雷达系统、基站或的应用中,都是需要尽可能精确的功率测量。这种要求不仅体现在实验室校准应用上,同时也体现在研发,生产,维修等应用中。
NRP-Z系列射频功率探头无论在实验室还是在生产线,微波功率计R&S NRP都是你正确的选择。新颖的R&S NRP系列功率计的通用性主要归因于新近开发的功率探头。这些探头是智能的独立仪器,他们与基本单元通讯,或经由数字接口与一个pc机通信。现在实现的智能传感技术,建立了根据通用性和准确性要求的新标准。
- R&S®NRP-Z11 Order No. 1138.3004.02 / 1138.3004.04Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -67 dBm to +23 dBm,
Frequency range: 10 MHz to 8 GHz,
N connector - R&S®NRP-Z21 Order No. 1137.6000.02Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -67 dBm to +23 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector - R&S®NRP-Z22 Order No. 1137.7506.02Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -57 dBm to +33 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector - R&S®NRP-Z23 Order No. 1137.8002.02Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -47 dBm to +42 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector - R&S®NRP-Z24 Order No. 1137.8502.02Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -42 dBm to +45 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector - R&S®NRP-Z31 Order No. 1169.2400.02 / 1169.2400.04Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -67 dBm to +23 dBm,
Frequency range: 10 MHz to 33 GHz,
3.5 mm connector
- R&S®NRP-Z211 Order No. 1417.0409.02Two-Path Diode Power Sensors
Cost-effective power measurement solution for production
Measurement range: -60 dBm to +20 dBm,
Frequency range: 10 MHz to 8 GHz,
N connector - R&S®NRP-Z221 Order No. 1417.0309.02Two-Path Diode Power Sensors
Cost-effective power measurement solution for production
Measurement range: -60 dBm to +20 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector
- R&S®NRP-Z51 Order No. 1138.0005.02Thermal Power Sensor
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: -30 dBm to +20 dBm,
Frequency range: DC to 18 GHz,
N connector - R&S®NRP-Z52 Order No. 1138.0505.02Thermal Power Sensor
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: -35 dBm to +20 dBm,
Frequency range: DC to 33 GHz,
3.5 mm connector - R&S®NRP-Z55 Order No. 1138.2008.03Thermal Power Sensor model .03
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: -35 dBm to +20 dBm,
Frequency range: DC to 40 GHz,
2.92 mm connector - R&S®NRP-Z55 Order No. 1138.2008.04Thermal Power Sensor model .04
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: -35 dBm to +20 dBm,
Frequency range: DC to 44 GHz,
2.92 mm connector - R&S®NRP-Z56 Order No. 1171.8201.02Thermal Power Sensor
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: –35 dBm to +20 dBm,
Frequency range: DC to 50 GHz,
2.4 mm connector - R&S®NRP-Z57 Order No. 1171.8401.02Thermal Power Sensor
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: –35 dBm to +20 dBm,
Frequency range: DC to 67 GHz,
1.85 mm connector - R&S®NRP-Z58 Order No. 1173.7031.02Thermal Power Sensor
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: –35 dBm to +20 dBm,
Frequency range: DC to 110 GHz,
1.00 mm connector
- R&S®NRP-Z81 Order No. 1137.9009.02Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 18 GHz,
N connector - R&S®NRP-Z85 Order No. 1411.7501.02Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 40 GHz,
2.92 mm connector - R&S®NRP-Z86 Order No. 1417.0109.40Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 40 GHz,
2.4 mm connector
- R&S®NRP-Z91 Order No. 1168.8004.02 / 1168.8004.04Average Power Sensor
Accurate average power measurements for EMC applications
Measurement range: -67 dBm to +23 dBm,
Frequency range: 9 kHz to 6 GHz,
N connector - R&S®NRP-Z92 Order No. 1171.7005.02 / 1171.7005.42Average Power Sensor
Accurate average power measurements for EMC applications
Measurement range: -57 dBm to +33 dBm,
Frequency range: 9 kHz to 6 GHz,
N connector
- R&S®NRP-Z28 Order No. 1170.8008.02Level Control Sensor
Highly accurate signal level generation in conjunction with a signal generator
Measurement range: -67 dBm to +20 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector - R&S®NRP-Z98 Order No. 1170.8508.02Level Control Sensor
Highly accurate signal level generation in conjunction with a signal generator
Measurement range: -67 dBm to +20 dBm,
Frequency range: 9 kHz to 6 GHz,
N connector
- R&S®NRP-Z27 Order No. 1169.4102.02Power Sensor Module (for use with R&S®FSMR)
Level calibration of signal sources in conjunction with the R&S®FSMR measurement receiver
Measurement range: -24 dBm to +26 dBm,
Frequency range: DC to 18 GHz,
N connector - R&S®NRP-Z37 Order No. 1169.3206.02Power Sensor Module (for use with R&S®FSMR)
Level calibration of signal sources in conjunction with the R&S®FSMR measurement receiver
Measurement range: -24 dBm to +26 dBm,
Frequency range: DC to 26.5 GHz,
3.5 mm connector
- R&S®NRPZ-K1 Order No. 1418.9800.03R&S®NRPV license for one R&S®NRP-Zxx power sensor
Convenient power measurements via PC application
- R&S®NRP-Z2 Order No. 1146.6750.03 / 1146.6750.05 / 1146.6750.10 / 1146.6750.15Sensor Extension Cable
In some cases the signal source is far away from the base unit. Therefore four different sensor extension cables are available, to get a total length of 3, 5 or 10 meters.
- R&S®NRP-Z3 Order No. 1146.7005.02USB Adapter (active)
R&S®NRP-Z3 active USB adapter has been developed for applications requiring external triggering of the power sensor. It also offers a separate power supply.
- R&S®NRP-Z4 Order No. 1146.8001.02 / 1146.8001.04 / 1146.8001.06 / 1146.8001.11USB Adapter (passive)
For all R&S®NRP-Z sensors. The R&S®NRP-Z4 passive USB adapter provides all basic functions, as it handles the transmission of settings and measurement data as well as the power supply of the sensor via the USB bus. Available cable lenghths: 2.0m, 0.5m, 0.15m and 1m (for panel-mount)
- R&S®NRP-Z5 Order No. 1146.7740.02USB Sensor Hub
R&S®NRP-Z5 can host up to 4 R&S®NRP-Z sensors. A professional trigger solution allows simultaneous internal and external triggering of all connected sensors.
功率计实物照片