菲尼克斯变送器MCR-F-UI-DC
Products
Description Type Order No. Pcs./Pkt
Universal Frequency Transducer MCR-f-UI-DC 2814605 1
菲尼克斯变送器MCR-F-UI-DC
General Data
Supply voltage 20…30 V DC
Current consumption (without load) < 60 mA (without switching output)
Transmission error < 0.15% of end value (typ. 0.1%)
Temperature coefficient < 0.015%/K (typ. 0,01%/K)
Test voltage:
Input/power supply
Input/output
Output/power supply
1.5 kV, 50 Hz, 1 min.
1.5 kV, 50 Hz, 1 min.
1.5 kV, 50 Hz, 1 min.
Protection circuit Transient protection, polarity protection
Ambient temperature range -20 °C...65 °C
Operation indicator LC display
Control panel Membrane keypad with 3 keys and LCD
Type of connection Pluggable screw connection
Installation position/assembly Any, preferably horizontal
Dimensions (W / H / D) 45 mm x 75 mm x 110 mm
Conductor cross section 0.2...2.5 mm2
Type of housing ASA-PC (V0)
Measurement Input, Frequency Input
Frequency range 0.1 Hz…120 kHz
Input sources – PNP transistor outputs
– NPN transistor outputs
– NAMUR initiators
– Potential-free relay contact (Dry Contact)
– Frequency generator
Sensor supply ca. 15 V DC / < 25 mA
Input frequency / peak time / resolution 0.1 Hz…120 kHz / ≤ 32 ms / ≥ 12 Bit
Signal level 2 Vpp (0.1 Hz…120 kHz)
2 Vpp (8.0 Hz…120 kHz)
18 Vpp (1.0 Hz…120 kHz)
max. 30 V (incl. DC voltage)
Pulse length ≥ 1μs
Current/Voltage Input
Input signal 0…10 V / 0…20 mA
Cut-off frequency 10 Hz
Ascent time (10...90%) 25 ms