北京北广精仪仪器设备有限公司郑重声明:* ,如有需要:请百度搜索(北京北广精仪仪器设备有限公司)
耐电弧试验机产品型号:BDH-B
一、耐电弧试验机主要适用范围及功能:
耐电弧试验机是按照GB1411 、IPC650、IEC61621、ASTMD495设计制造,并符合JEC149、UL746A等试验方法。应用于电机、电器和家用电器等行业的电工用塑料、树脂胶和绝缘漆等绝缘材料的耐电弧性能评定。主要适用于固体绝缘材料如:塑料、薄膜、树脂、云母、陶瓷、玻璃、绝缘油、绝缘漆、纸板等介质的耐电弧性能测试;耐电弧试验机采用计算机控制,试验过程中可在线观察试验曲线;自动存储试验条件及试验结果等数据,并可存取、显示、打印.
·耐电弧试验机试验过程描述:
过程 弧电流/mA 通断时间/秒 持续时间/秒 试验所经时间/秒
1/8-10 10 1/4s通 7/4s断 60 60
1/4-10 10 1/4s通 7/4s断 60 120
1/2-10 10 1/4s通 7/4s断 60 180
10 10 导通 60 240
20 20 导通 60 300
30 30 导通 60 360
40 40 导通 60 420
Dry solid high arc test instrument for small current arc discharge tester dry solid high arc tester small current arc discharge tester
Simple introduction:
The product model BDH-B
The main scope of application and function:
The testing machine is in accordance with the GB1411, IPC650, IEC 61621, ASTMD495 design and manufacturing, and in accordance with JEC 149, UL 746A test method.
Used in motors, electrical and household appliances industries such as electrical plastic, resin adhesive and insulating paint and other insulating materials arc resistance performance evaluation
Mainly applicable to solid insulation materials such as: plastic, film, resin, mica, ceramic, glass, insulating oil, insulating paint, and other medium arc resistance performance test;
二、耐电弧试验机主要技术要求:
1、输入电压: 交流 220 V
2、输出电压: 交流 0--20 KV ;
3、电器容量: 1.5 KVA
4、试验方式: 间歇电弧,连续电弧
5、试验电流: 10MA-20MA-30MA-40MA可选
6、试验电压控制误差: ≤ 1%
7、电弧通断时间误差: <5ms
8、试验电压连续可调: 0--20 KV
9、电极规格:不锈钢板状电极 25.4mm*12.7mm*0.15mm
钨钢电极 56mm*7mm*30mm
电极配置角110度
电极重量:50G
10、安全防护措施: (1)超压保护
(2)过流保护
(3)短路保护
(4)安全门开启保护
(5)软件误操作保护
Arc resistance test machine controlled by computer, test process can be online observation test curve; automatic storage test conditions and test results and other data, and can access, display, print.
Description of test procedures
Process of arc current of /mA on-off time / sec duration / second test by the time / sec
1/8-10 10 1/4s 7/4s 6060
1/4-10 10 1/4s 7/4s 60120
1/2-10 10 1/4s 7/4s 60180
The 1010 conducting 60240
The 2020 conducting 60300
The 3030 conducting 60360
The 4040 conducting 60420
The main technical requirements:
In 1, the input voltage: AC 220 V
In 2, the output voltage: AC 0--20 KV;
3, electrical capacity: 1.5 KVA
4, test : intermittent arc, continuous arc
5, test current: 10MA-20MA-30MA-40MA optional
In 6, the test voltage control error:≤ 1%
三、耐电弧试验机主要配置:
1、试验主机一台
2、2万伏高压发生器一台
3、全自动微电脑电压调压装置一套(串口方式)
4、电压采集及电流采集隔离式变送装置一套
5、试验电极:两套
6、放电棒一只(树脂式)
7、计算机耐电弧测控软件一套
8、计算机一套(联想品牌)
电脑主机配置:1、160G硬盘 2、2G内存 3、DVD光驱
显示器配置:17寸纯平液晶显示器一台
9、彩色喷墨打印机一台(惠普品牌)
10、程序光盘一套
11、产品使用说明书一份
12、计量检定证一份(省计量检测院)
13、合格证一份
14、随机工具一套