2016年10月18日 14:47:39人气:886来源:西安绿盛电气自动化设备有限公司


压力显控器 ( 以下简称仪表 ) 是在受压时,借助于弹性元件的位移同时进行压力指示和控制的新型自控仪表,由于采用了双重弹性元件分别进行压力指示和控制,因而其精度大幅度提高,同时具有结构合理,控制精度高、稳定可靠、抗震性*。触点容量大,使用安装方便,可以进行现场调整等优点。
   The pressure control monitor (hereafter refers to as the instrument) is a new kind of automatic control instrument that carries out the pressure indication and the control simultaneously with the aid of the displacement of elastic elements under pressure. Since it adopts the dual elastic elements to carry out the pressure indication and the control respectively, its precision rises substantially. At the same time, it has many advantages such as reasonable structure, high control precision, steady reliable, superior anti-seismic performance and large contact capacity, convenient to use and install as well as adjustable on-the-spot.
二、用途(Usage):
   本仪表适用于对无爆炸危险的非结晶和凝固的无腐蚀性介质压力进行一位或二位式控制。
   This instrument is suitable for one or two type control to the amorphous substance with no explosion hazard and the coagulate medium without corrosiveness.
三、主要技术参数(Main technical parameter):
 1. 规格(Specifications):单位为MPa(The unit is MPa)
          注(Note):1 MPa = 10.2 Kgf/em²

  0-0.4; 0-0.6; 0-1; 0-1.6; 0-2.5; 0-4; 0-6; 0-10; 0-16; 0-25; 0-40; 0-60; 0-100.

2. 压力指示精度(Pressure indication precision): 1.5

 3. 压力控制精度(Pressure control precision): 0.5

 4. 压力控制范围,压力指示上限值的5-70%(Pressure control scope: 5-70% of the pressure instruction upper limit )

 5. 控制方式(Control mode):
(一)一位式控制(常闭或常开)A type control (closes or opens frequently)
(二)二位式控制(常闭或常开)Two type control (closes or opens frequently)
6. 压力差动值(Pressure differential value):
 不大于压力控制范围上限值的10%(Not larger than 10% of the upper pressure control scope limit.)

7. 触点容量 380V x 2A   220V x 3A(Contact capacity: 380V x 2A   220V x 3A)

 8. 使用频率:≤25次/分(Frequency of use: ≤25 times / minute)
 9. 使用环境条件:‐40 ― + 60℃相对温度不大于85%(Operating ambient conditions: ‐40 ― + 60℃.The relative temperature is not bigger than 85%.)

四、结构原理(Structural principle):

 仪表由弹性元件,控制机构、调整机构、指示装置,表壳及接线盒等组成。

 其工作原理是:在介质压力作用下,弹簧管末断产生位移,当压力达到所设定的控制值时,推动微动开关产生瞬间开关动作,使控制系统中的电路得以通断切换,达到自动控制或发出信号的目的。

   The instrument is composed of elastic element, control mechanism, adjusting mechanism, indicating device, watch case and wiring box and so on.

   Its working principle is: Under the medium pressure, the spring tube terminal produces displacement. When pressure reaches the control value set, the jogging switch is promoted to produce instant switch movement. This makes the electric circuit in control system on-and-off so that the purpose of automatic control or sending out the signal is reached.

五、使用与调整(Use and adjustment):

  1. 设定值调整(Setting value adjustment):

  (一)将仪表和精密压力表(可用自身的压力表)连接在压力校验台上,然后按下图接通电源:

  Connect the instrument and the precise manometer (your own manometer available) on the pressure checking table. Then connect the power source according to the following drawing:

 所用材料(Materials to be used):1.5V电池两节(two 1.5V batteries)3V灯泡二个(two 3V light bulbs)

   (二)升压,将螺丝刀插入调整窗孔内,通过旋拧调整螺钉进行设定值调整,当指示灯产生瞬间亮或灭时,其指针指示的压力值应正好为设定值。

  Raise the pressure and insert the screwdriver to the adjustment window hole. Adjust the setting value by turning and twisting the adjusting screw. When indicator light produces instant bright or extinguishes, the pressure value that the indicator indicated should happen to be the setting value.

  2. 现场调整(Adjustment on-the-spot):

  通过设定值调整,将仪表装机后或在使用中,若示值偏离设定值,利用仪表的指示装置进行现场调整。

  After the setting value is adjusted and the instrument is packed, or when the instrument is in use, if the indicating value deviates the setting value, the instrument can be adjusted on-the-spot by using its indicating device.

  3. 仪表的选用(Instrument selection):

  选用仪表时,应按其使用的zui大压力值再加三分之一进行计算选用。

  The instrument should be chosen by calculating the maximum value of its use plus 1/3 of this value.

  4. 仪表在使用过程中,应经常保持干燥、洁净,并定期进行检修,以确保其准确,可靠地工作。

  In the process of using, the instrument should be kept dry and clean frequently, and should be overhauled regularly so as to ensure that it works accuray and reliably.

六、安装尺寸图(Ⅵ. The Dimensional Drawing of Installation):

       

          

单位Unit:mm

型号Type

结构Structure

D

D1

D0

d

B

B1

B2

I

I1

b

H

H1

L

YXK-100

径向无边

Boundless in radial direction

¢100

¢110

 

 

99

25

35.5

23

13.5

19

85

36

 

YXK-101

轴向前边

Axial front

¢100

¢110

¢118

¢130

99

25

 

23

13.5

20

29

36

130

YXK-103

轴向无边

Axial boundless

¢100

¢110

¢118

¢130

99

25

 

23

13.5

19

29

36

130

YXK-150

径向无边

Boundless in radial direction

¢150

¢160

 

 

102

25

35.5

23

13.5

19

110

67

 

YXK-151

轴向前边

Axial front

¢150

¢160

¢165

¢190

102

25

 

23

13.5

20

29

67

140

YXK-153

轴向无边

Axial boundless

¢150

¢160

¢165

¢190

102

25

 

23

13.5

19

29

67

140

七、订货须知:
Ⅶ. Ordering notice:
订货时请注明:

Please indicate when ordering:

1. 型号及名称;
1. Model and Name;
2. 规格;
2. Specifications;
3. 压力差动值;

3. Scope of Pressure Differential Value;

4. 其它特殊要求。

4. Other Special Requirements.

 

全年征稿/资讯合作 联系邮箱:1271141964@qq.com

免责声明

  • 凡本网注明"来源:智能制造网"的所有作品,版权均属于智能制造网,转载请必须注明智能制造网,https://www.gkzhan.com。违反者本网将追究相关法律责任。
  • 企业发布的公司新闻、技术文章、资料下载等内容,如涉及侵权、违规遭投诉的,一律由发布企业自行承担责任,本网有权删除内容并追溯责任。
  • 本网转载并注明自其它来源的作品,目的在于传递更多信息,并不代表本网赞同其观点或证实其内容的真实性,不承担此类作品侵权行为的直接责任及连带责任。其他媒体、网站或个人从本网转载时,必须保留本网注明的作品来源,并自负版权等法律责任。
  • 如涉及作品内容、版权等问题,请在作品发表之日起一周内与本网联系,否则视为放弃相关权利。

<
更多 >

工控网机器人仪器仪表物联网3D打印工业软件金属加工机械包装机械印刷机械农业机械食品加工设备制药设备仓储物流环保设备造纸机械工程机械纺织机械化工设备电子加工设备水泥设备海洋水利装备矿冶设备新能源设备服装机械印染机械制鞋机械玻璃机械陶瓷设备橡塑设备船舶设备电子元器件电气设备


我要投稿
  • 投稿请发送邮件至:(邮件标题请备注“投稿”)1271141964.qq.com
  • 联系电话0571-89719789
工业4.0时代智能制造领域“互联网+”服务平台
智能制造网APP

功能丰富 实时交流

智能制造网小程序

订阅获取更多服务

微信公众号

关注我们

抖音

智能制造网

抖音号:gkzhan

打开抖音 搜索页扫一扫

视频号

智能制造网

公众号:智能制造网

打开微信扫码关注视频号

快手

智能制造网

快手ID:gkzhan2006

打开快手 扫一扫关注
意见反馈
关闭
企业未开通此功能
详询客服 : 0571-87858618